To splice low voltage landscape wire, turn off the transformer first, then strip each wire end and join the pieces with a connector rated for direct burial. The two manufacturers the sources include, CAST Lighting and VOLT Lighting, agree on the order: power off, clean and strip, connect and test before burying. Their connectors differ.

If you want to know how to splice low voltage landscape wire, turn off the transformer first, then strip each wire end and join the pieces with a connector rated for direct burial. The two manufacturers the sources include, CAST Lighting and VOLT Lighting, agree on the order: power off, clean and strip, connect, and test before burying. Their connectors differ.

This guide is for the low voltage side of an outdoor lighting system, the cable that runs from the transformer to the fixtures. It is not a guide to line voltage wiring. If your transformer or any wiring is connected to household power, the steps below do not replace the advice of a licensed electrician.

At a glance

  • Turn off the outdoor lighting transformer before you touch any wire. VOLT Lighting also advises unplugging it from the power source.
  • Clean the insulation and strip the ends. CAST Lighting says to wipe the insulation 2 inches from the cut end with a damp cloth and dry it before stripping.
  • Use a connector rated for direct burial. Both manufacturers describe their connectors that way.
  • Test the connection with the power back on, then bury the cable.

Before you start: what the sources say

Both guides begin with the power. The VOLT Lighting guide lists the first step as “Turn Off the Power,” and says, “Before doing anything else, turn off the outdoor lighting transformer.” It adds: “For extra safety, unplug the transformer from the power source entirely before you begin working.”

The CAST Lighting sheet is written for its repair kit, which it describes as “for the Repair of Landscape Lighting, Irrigation, Speaker and Other Control Wires.” The sheet does not repeat the power step in the same words, so use the VOLT guide’s advice as well. Power down first, every time.

Step 1: Clean the insulation

The CAST sheet starts with cleaning. Its first step reads: “Using a damp cloth, wipe clean wire insulation 2″ from cut ends. Dry completely with dry cloth.” The point of this step is to remove dirt, grease, and moisture from the jacket where the heat shrink or sealant will sit. A clean surface gives the sealant and the tubing a better grip. The sheet does not say what would happen if the surface is left dirty, so treat the step as a preparation step rather than a fix for a known failure.

Dry the cable completely before you go on. The sheet says to dry the insulation with a dry cloth. Working with a wet cable makes it harder to get a tight seal around the connector.

Step 2: Strip the wire ends

Strip each wire end to expose bare copper. The two guides give different lengths because they describe different connectors. The VOLT guide says to “remove the insulation from each wire end to expose approximately half an inch of bare copper” for its wire nut. The CAST sheet gives lengths by wire size. For #12/2 and #10/2 cable, it says “expose 3/8″ bare wire.” For #16/2 cable, it says “expose 1/4″ bare wire.”

Use the length the connector maker gives, not a length from memory. The sources give these lengths for their own connectors, and the sheets do not say what happens with a different length.

Method Stated strip length Connector Stated sealing
CAST Lighting butt splice, #12/2 and #10/2 3/8 inch bare wire 12-10 butt connector, crimped with the supplied tool 3/8 inch heat shrink tubing, heated until it shrinks tight
CAST Lighting butt splice, #16/2 1/4 inch bare wire 16-14 butt connector 3/16 inch heat shrink tubing
VOLT Lighting silicone wire nut About half an inch of bare copper Waterproof wire nut, twisted clockwise Silicone fill inside the connector, stated as rated for direct burial

The table uses the figures from the two sheets. Where a sheet does not state something, such as the tool needed for the wire nut, we leave the cell out rather than guess.

Step 3A: Splice with a butt connector and heat shrink

The CAST method for a line-to-line splice uses a metal butt connector, a crimping tool, and heat shrink tubing. The sheet’s steps are: slip the heat shrink tubing over the insulation on one of the wires, insert the bare wire from both pieces into both ends of the butt connector, and crimp each side firmly with the supplied tool. Then slip the tubing over the connector. The sheet says, “apply heat evenly over the surface of the tubing using a heat gun or flame*. Continue to apply heat until the tubing shrinks tightly over the insulation and connector.”

The sheet gives a note on heat. It says, “*For best results use electric heat gun – not open flame.” Use the heat gun the sheet recommends. Keep the heat moving so the tubing shrinks evenly and does not scorch the insulation.

The sheet also says each leg of a paired wire needs its own connection. Low voltage landscape cable usually has two conductors, and each one must be spliced separately. Do not join both legs into one connector.

For a socket wire joined to a lead wire, CAST describes a parallel crimp connector. Strip the two wires to 1/4 inch, place them side by side in the parallel crimp connector, crimp firmly, then cut a 3/4 inch piece of 3/16 inch heat shrink, slip it over the connector, and shrink it with heat. That is a different joint from a run splice, so use the method that fits the cable you are joining.

Step 3B: Splice with a waterproof wire nut

The VOLT method uses a silicone-filled waterproof wire nut. Its steps are to strip the wire, align the wires side by side, and insert the twisted ends into the connector. The guide says to “Insert the twisted wire ends firmly into the DryConn® waterproof wire nut and twist the connector clockwise.” It describes the silicone fill as the sealing method: “The silicone-filled wire nuts are rated for direct burial and will maintain a waterproof seal underground season after season.”

The VOLT guide also says silicone-filled wire nuts are “the most straightforward option for direct burial landscape lighting connections.” That is the manufacturer’s view of its own product type. It does not compare the wire nut with a crimp joint in performance terms, so do not read it as a claim that one method always beats the other.

Twist the connector clockwise until it is firm, then check that no bare copper shows outside it. If the wires do not seat, strip them to the length the guide gives and try again. Do not force a connector onto wire that does not fit it.

Step 4: Test before you bury

The VOLT guide puts the test before the burial. After the connections are made, “Turn the power back on to the outdoor lighting transformer and confirm the connected fixture lights up.” Only then does it say to “bury the cables and connectors.” The order matters. If a fixture does not light, you want to find the fault while the cable is still above the ground.

Once the power is back on and the fixture works, bury the splice in the way the connector maker describes. The CAST sheet and the VOLT guide both describe their connections as waterproof, but neither source gives a burial depth in this material. Check your local code and the cable maker’s instructions for the depth.

Choosing a connector

Pick a connector that matches the wire gauge and the job. The CAST kit lists separate butt connectors for 12-10 and 16-14 wire, plus parallel crimp connectors for socket wire. The VOLT guide says its wire nut is the simplest option for direct burial, and it also lists clamp-type hub connectors and crimp and barrel connectors for other installations. A connector that is too small will not fit the wire. A connector that is too large may not seal well.

Read the listing. Look for the stated wire gauge range and the direct burial rating before you buy. If the listing does not state a gauge range, it does not tell you whether the connector fits your cable.

Common mistakes

  • Splicing with the transformer on. Both guides start with power off. The VOLT guide says to unplug the transformer entirely for extra safety.
  • Stripping too little or too much. Use the length the connector maker gives for that connector.
  • Skipping the cleaning step. The CAST sheet asks for a clean, dry surface before the joint is made.
  • Joining both legs into one connection. The CAST sheet says each leg needs its own connection.
  • Burying before testing. The VOLT guide puts the test before burial for a reason.

What remains unclear

  • Neither source gives a burial depth for direct burial cable, so this article does not give one.
  • The sources do not state a maximum current or wattage for a given splice. Check the connector’s listing and your transformer’s rating.
  • The sources do not compare the long-term performance of a crimp splice and a wire nut in the same soil conditions.
  • We did not check a full step-by-step sheet for every connector brand. The steps here come from the two sources named above.

Frequently asked questions

Do I have to turn off the transformer to splice low voltage wire?

Yes, according to the VOLT guide, which says to turn off the outdoor lighting transformer before doing anything else and to unplug it from the power source for extra safety.

How much wire should I strip?

It depends on the connector. The VOLT guide gives about half an inch for its wire nut. The CAST sheet gives 3/8 inch for #12/2 and #10/2 cable and 1/4 inch for #16/2 cable. Use the length for your connector.

Can I use heat shrink tubing with a wire nut?

Neither source says so, so this article does not recommend it. The CAST sheet pairs heat shrink with its butt connectors. The VOLT guide relies on the silicone fill of its wire nut.

What is the difference between a butt connector and a wire nut?

A butt connector is a metal tube that is crimped onto both wires, as in the CAST method. A wire nut is a plastic cap that is twisted onto twisted wire ends, as in the VOLT method. The sources describe each as a splice method for low voltage landscape cable.

Do I need a special tool?

For the CAST butt connector, the sheet says to use the supplied crimping tool and an electric heat gun. For the VOLT wire nut, the guide lists wire strippers among the tools. Check the kit or connector for what it includes.

Bottom line

Turn off the power, clean and strip the wire to the length your connector needs, join each leg with a direct burial connector, test with the power on, then bury the splice. If you are not sure the power is off or the connection is right, stop and ask a licensed electrician.

Before you cut any cable, plan the run. For a walkway layout, see our garden path lighting guide. If your lights are solar powered and need no wire, see our pathway solar lights roundup instead.

Sources

  • CAST Lighting, “Wire Repair Splice Kit Instructions,” model CLWSK, https://cdn.shopify.com/s/files/1/1916/1697/files/clwsk-wire-repair-splice-kit-by-cast-lighting-instruction.pdf
  • VOLT Lighting, “How to Make a Low Voltage Wire Connection,” https://www.voltlighting.com/learn/how-to-make-low-voltage-wire-connections